Categories Cycling

FAQ: Vaillant anti cycling mode?

What does Vaillant Anti-cycling mode mean?

Sometimes the boiler enters an anticycling mode, which is intended to prevent it from trying to re-start inappropriately quickly. In other words, for a target flow temperature of 70C, his boiler is using the values that the table gives in the 65C row.

Why does the egg timer keep appearing?

When an egg timer symbol appears on one of the zones, it means that the temperature between the HR92 and evohome is not synchronized. In order to see the temperature for that zone again, you will need to go to this specific HR92, press the main button until the backlight is on and then go back to the controller.

What is comfort mode on a Vaillant boiler?

When you close the hot water tap. the boiler automatically stops producing hot water. If you have activated Comfort mode, the boiler supplies you with hot water at the requested temperature without you having to wait for the water to heat up.

You might be interested:  FAQ: Garmin watch for cycling?

What does the timer sign mean on a Vaillant boiler?

Something is telling the boiler it needs to be heating, hence the radiator symbol. The flashing timer means the boiler is cycling. Its basically up to the temp set (66 degrees) and no further heat required. Flashing radiator burner is operating. It may be a Nest fault.

What is anti cycling mode?

Anticycling time explained



To prevent the boiler from switching on and off constantly in a short time, this function adds a time delay. This function is used only for heating mode and not hot water. The timer will again be activated each and everytime the boiler needs to enter anticycling mode.

Do Vaillant boilers have frost protection?

This two-stage frost protection feature is only active when the boiler is switched on. The boiler alone cannot ensure the installation is protected against frost. A separate thermostat may be necessary to control the temperature of the system. The frost protection feature can vary amongst our appliances.

What does the egg timer symbol mean on products?

Any cosmetic product that has a lifespan of less than 30 months must show a “Best before the end of” date. This can be shown using the “egg timersymbol followed by the date, or the words, which can be abbreviated to BBE or Exp, followed by the date.

Does Windows 7 have a timer?

Microsoft has introduced some amazing new features in Windows 7. I have used these features to create this small app: taskbar, jump-list, task-dialog, and Aero Glass. The application is just an egg-timer: you tell the time after which the timer must elapse, and it shows you the time left.

You might be interested:  Quick Answer: Spd sl cycling shoes?

Why does my Vaillant boiler keep turning off?

The boiler has a temperature sensor that checks the water temperature. a closed valve: Lack of proper water flow can cause the boiler to turn off. Check and make sure that all valves are open so that the water flow is not obscured. low water pressure: Check for leaks that may be causing the water pressure to lessen.

What temperature should I set my Vaillant boiler to?

Boiler thermostat: this should be set at 65 degrees, to enable it to deliver water of 60 degrees (see above). While radiators will get hot quicker if the boiler thermostat is set at a higher temperature, the boiler may not condense, which will reduce its efficiency by 10-20%.

How do I reset my Vaillant Ecotec Plus?

To reset the boiler manually, press the reset button (3) and hold for one second. If you are unable to resolve the ignition problem yourself by resetting the boiler three times, then consult your approved competent person.

How do I lower the pressure on my boiler?

How to reduce your boiler pressure

  1. Switch off your boiler and wait for the heating system to cool.
  2. Identify and check the boiler pressure gauge.
  3. If it’s above 2 bars, you’ll need to reduce the pressure.
  4. Ensure the filling loop or relief valve is tightly closed.

How do I increase the water pressure in my Vaillant boiler?

Locate the filling loop, often found on the underside of your boiler. Open both valves to allow water into your heating system. Keep an eye on the pressure gauge and close the valves when the pressure reaches 1.5 bar. Switch on your boiler and reset the fault code (if necessary).