Categories

Quick Answer: Mira sprint 10.8?

What is the difference between 8.5 kW and 10.5 kW shower?

Going back to the description of the electric showers, if you want your water hotter, the flow has to be slower. Higher powered electric showers have been introduced to combat this issue, so a higher power 10.5kW shower will be able to run at higher pressure at higher temperatures than 8.5kW electric showers.

Can I replace a 9kw shower with a 10.8 kW?

10.8kW Shower is going to require a 50A MCB and possibly 10mm twin and earth cable, your existing cable although not totally sure looks to be 6mm and not really suitable for a 50A device.

Which is the best Mira electric shower?

The Mira Sport Max 10.8kw is the perfect middle ground between the Triton Seville and the Bristan Bliss. It’s not digital, but it offers a slightly more modern design when directly compared to the Seville. And, it’s got the biggest kW output of all the showers on this list; it’s powerful.

Can I replace a 7.5 kW shower with a 8.5 kW?

4 Answers from MyBuilder Bathroom Fitters



A 7.5kw shower can be supplied using a 4mm cable, but for 8.5kw, you will need at least 6mm cable. Changing the fuse/circuit breaker would allow the shower to work but the cable could overheat and presents a fire risk.

Are Mira Showers any good?

All Mira digital showers are quick and easy to fit, as well as being suitable for any type of domestic plumbing system. Their range of wireless digital showers have precise temperature and flow control, making them accurate and informative.

Can I replace a 9kW shower with a 9.5 kW?

you don’t have to change the wiring, what you have will do fine. just check that the mcb is big enough, some electric showers call for 45 amp – though if you are going down from a 9.5 to a 9kw it should be fine.

Can you run a 9.5 kW shower on 6mm cable?

9.5kW is either 39A or 41A depending on the voltage it is rated at. 6mm cable is 47A when installed in the most favourable conditions. So 6mm could be used, depending on how it is installed. However it would be usual to use 10mm which would allow the fitting of a higher rated shower either now or in the future.

How many amps does a 8.5 kW shower use?

8.5KW shower (8500/230=37 amps)

Do I need a plumber or electrician to install an electric shower?

If you’re having a new electric shower installed, you will need to hire a Part P certified plumber who can safely complete the shower installation ensuring all wiring is in the correct places. Replacing an electric shower still requires plumbing and electrical experience, as your new shower may have higher wattage.

What is Mira Airboost?

Mira Airboost™ works by an air induction into the water stream, boosting performance through the speed of water coming through the showerhead. At a touch of a button, it increases the flow of water by up to 30% giving the feeling of more water without actually using any extra water at all.

What is the most powerful shower?

A 10.8kw electric shower is the most powerful electric shower there is and it means that it will provide improved pressure and a higher water temperature. For the best performance, 10.8KW electric showers need a minimum of 1.5 bar water pressure with a flow rate of 11 litres a minute.

How do you remove a Mira Sport shower cover?

Isolate the electrical and water supplies before installing the shower. Remove the three screws that hold the cover on and remove the cover. Remove the service tunnel.